Advertisements

biscologo

 

JournalCover

August 2026 Abstracts

_______________________________________________________________________________________________________________________________________________________________

                                                                                                                                                  Research Article

_______________________________________________________________________________________________________________________________________________________________

Effect of fiber post materials and timing of coronal preparation on sealing ability of post-core systems: A factorial design study

 

Chen Qu, mm  &  Xiangling Liao, md

 

Abstract: Purpose: To examine the effects of fiber post material and coronal preparation timing on the sealing ability of post-core systems and to determine whether these factors interact under thermal and mechanical aging conditions. Methods: A 2×2 factorial design was used. 60 freshly extracted single-rooted premolars meeting predefined inclusion and exclusion criteria were randomly assigned to four groups (n= 15): fiber-reinforced composite (FRC) post with immediate preparation, FRC with delayed preparation, prefabricated quartz fiber (PQF) post with immediate preparation, and PQF with delayed preparation. Post space length was standardized to 10 mm while maintaining a 4 mm apical seal, in accordance with the recommendation that post length should approximate two-thirds of root length and at least equal the clinical crown height. All procedures were completed by a single prosthodontist. Specimens underwent 5,000 thermal cycles followed by 240,000 cyclic loading cycles. Interfacial microgap width was serially evaluated by SEM at two time points, namely after thermocycling and after cyclic loading, and the data were analyzed with a linear mixed-effects model. Results: Post material type (F= 45.32, P< 0.001, η²p= 0.43) and time point (F= 312.56, P< 0.001, η²p= 0.84) showed significant effects, as did the material×time interaction (F= 8.73, P=0.004, η²p= 0.13). Preparation timing was not significant (F= 2.15, P= 0.148). After thermocycling, group B showed smaller microgap width than group D (3.91± 0.87 vs. 5.62± 1.77 μm; mean difference, -1.71 μm; 95%CI: -2.76 to -0.66; P=0.003). After cyclic loading, Group A was smaller than Group C (13.97± 1.89 vs. 17.85± 2.83 μm; mean difference, -3.88 μm; 95%CI: -5.62 to -2.14; P< 0.001), and Group B was smaller than group D (8.84± 1.98 vs. 13.29± 2.85 μm; mean difference, -4.45 μm; 95%CI: -6.22 to -2.68; P< 0.001). No root fractures were detected during specimen preparation, thermocycling, or cyclic loading. (Am J Dent 2026;39:166-172).

 

 

Clinical significance: For a given fiber post material, immediate and delayed coronal preparation produced comparable marginal sealing. Compared with prefabricated quartz fiber posts, fiber-reinforced composite post-core systems provided superior interfacial stability after aging and may be preferable in roots with irregular or flattened canal morphology.

 

 

Mail: Dr. Xiangling Liao, Department of Stomatology, Beijing Luhe Hospital Affiliated to Capital Medical University, No. 82 Xinhua South Road, Tongzhou District, Beijing 101149, China.  E-mail:  liaoxiangling114@163.com

 

 

_______________________________________________________________________________________________________________________________________________________________

                                                                                                                                                  Research Article

_______________________________________________________________________________________________________________________________________________________________

Fibromyalgia and acute periapical abscesses

 

Ilan Rotstein, dds  &  Joseph Katz, dmd

 

Abstract: Purpose: This cross-sectional study was to assess the prevalence of acute PAs in fibromyalgia patients. Methods: Nine years of data from 2,108,676 patients were retrieved and analyzed by searching corresponding ICD-10 diagnosis codes for fibromyalgia and acute PAs. The odds ratio (OR) for acute PAs and their association with fibromyalgia were calculated and statistically analyzed using MEDCALC software at the 95% confidence level. Logistic regression and adjustment for diabetes, nicotine dependence, and alcohol use disorder comorbidities were done. Results: Overall, the OR for acute PAs in patients with fibromyalgia was 4.7, and the difference in prevalence compared to the total hospital patient population was statistically significant (P< 0.0001). After adjustment for diabetes, the OR was 2.8. After adjustment for nicotine dependence, the OR was 2.6. After adjustment for alcohol related disorders, the OR was 4.4. The difference in prevalence compared to the total hospital patient population remained statistically significant (P< 0.0001). (Am J Dent 2026;39:173-176).

 

 

Clinical significance: Clinicians should be aware of the possible higher prevalence of periapical abscesses in patients with fibromyalgia. More frequent dental visits for caries control and pulp disease prevention are warranted.

 

 

Mail: Dr. Ilan Rotstein, Department of Endodontics and Periodontics, University of Southern California, 925 West 34th Street, Suite 310, Los Angeles, CA 90089-0641, USA. E-mail: ilanrotstein@gmail.com

 

 

_______________________________________________________________________________________________________________________________________________________________

                                                                                                                                                  Research Article

_______________________________________________________________________________________________________________________________________________________________

Oral malodor control with a stabilized stannous fluoride toothpaste compared to sodium monofluorophosphate: A randomized controlled trial

 

Dutmanee Seriwatanachai, phd, Terdphong Triratana, dds, Luis R. Mateo, ma, Robert D’Ambrogio, bsc &  Yun-Po Zhang, phd, dds (hon)

 

Abstract: Purpose: To evaluate the clinical efficacy of a test toothpaste containing 0.454% stannous fluoride stabilized with zinc phosphate as compared to a control fluoride toothpaste containing 0.76% sodium monofluorophosphate on oral malodor reduction via organoleptic scores after 3 weeks of twice daily product use. Methods: A randomized, single-center, double-blind, parallel-group clinical trial conducted in Bangkok, Thailand. Eighty adult subjects with qualifying baseline oral malodor scores were randomized to use either the test toothpaste or the control toothpaste twice daily for 3 weeks. Efficacy was assessed using the organoleptic hedonic scale (1-9) by four calibrated judges. The primary endpoint was the reduction in organoleptic scores assessed 12 hours post-brushing (overnight). Results: All 80 subjects completed the protocol. At baseline, there were no significant differences in organoleptic scores between groups (P= 0.816). After 3 weeks, the Test group showed a 37.8% reduction from baseline in overnight malodor scores (P< 0.001), while the Control group showed a 13.6% reduction (P< 0.001). The Test group demonstrated a statistically significant (P< 0.001) 28.0% greater reduction in oral malodor compared to the Control group. No adverse events were reported. (Am J Dent 2026;39:177-180).

 

 

 

Clinical significance: The 0.454% stannous fluoride toothpaste stabilized with zinc phosphate provided a superior, long-lasting solution for overnight oral malodor management compared to a standard sodium monofluorophosphate toothpaste after 3 weeks of use.

 

 

 

Mail: Dr. Yun-Po Zhang, Colgate-Palmolive Co., 909 River Rd., Piscataway, NJ 08854, USA. E-mail: yun_po_zhang@colpal.com

 

 

_______________________________________________________________________________________________________________________________________________________________

                                                                                                                                                  Research Article

_______________________________________________________________________________________________________________________________________________________________

Effects on adjacent enamel and dentin of restorations using bioactive materials under laboratory caries condition

 

Bettina Gabriela Ferreira do Amaral, dds, Leonardo Santos Barros, dds, msc, Milagros Falcon Aguilar, dds, msc, Flávio Henrique Baggio Aguiar, dds, msc, phd, Cecilia Pedroso Turssi, dds, msc, phd, Roberta Tarkany Basting, dds, msc, phd, & Waldemir Francisco Vieira-Junior, dds, msc, phd

 

Abstract: Purpose: This study evaluated the cross-sectional Knoop microhardness (KHN) of enamel and dentin adjacent to restorations made with bioactive materials, and their surface degradation after pH cycling. Methods: Molar blocks (n=10) were restored with conventional resin composite (RC; Z350XT), resin-modified glass-ionomer cement (R-GIC; Vitremer), flowable compomer (FC; Twinky), resin composite with S-PRG filler (RC-S-PRG; Beautifil II), or self-curing bioactive composite (RC-SP; Cention N). After pH cycling, KHN was measured at 100, 200, and 300 µm from the restoration margins and at depths of 20, 40, and 60 µm from the surface. Surfaces were evaluated using scanning electron microscopy (SEM). Data were analyzed via split-plot ANOVA and Tukey’s test (α=0.05). Results: Regardless of material, enamel KHN was lower at 20 µm than at 60 µm depth (100 µm distance), at 40 µm than at 60 µm depth (300 µm distance), and dentin KHN was also lower at 20 µm. RC and R-GIC showed reduced dentin KHN at 20 µm compared to 60 µm. SEM analysis revealed surface degradation in all materials (RC<R-GIC<FC<RC-S-PRG<RC-SP). (Am J Dent 2026;39:181-186).

 

Clinical significance: The ion-releasing bioactive materials did not provide superior protection of microhardness compared with the conventional composite. Moreover, bioactive materials exhibited greater surface degradation after acidic challenge, which may compromise their long-term stability in the oral environment.

 

Mail: Dr. Waldemir Francisco Vieira-Junior, Piracicaba Dental School, University of Campinas, Av. Limeira, 901 - CEP 13414-903, Piracicaba, SP, Brazil.  E-mail: waljr@unicamp.br

 

 

 

_______________________________________________________________________________________________________________________________________________________________

                                                                                                                                                  Research Article

_______________________________________________________________________________________________________________________________________________________________

Effect of faucet-mounted water filters on the fluoride and calcium concentrations of tap water

 

Ahmed S. Aljuaid, bds, msd, sbrd,  Armando E. Soto-Rojas, dds, mph,  Laila Al Dehailan, bds, msd, phd, Fahad S. Algahtani, bds, cags, msc, phd,  George J. Eckert, mas   &   Frank Lippert, phd

 

Abstract: Purpose: To evaluate the effect of faucet-mounted water filters (FMWF) on the fluoride and calcium concentrations in tap water during their use. Methods: A convenience sample of 15 different brands of FMWF was investigated (PUR, Brita, Waterdrop, Culligan, Engdenton, DuPont, Instapure, iSpring, OEMIRY, IVO, SJ WAVE, WINGSOL, ZeroWater, AIBERLE, MIST). Water samples were collected before the installation and after removal of the filters to determine baseline fluoride and calcium values. After mounting the filters, samples were collected after 1, 5, 10, 30, 50, 75, and 100 liters of water passed through each filter. Fluoride analysis was performed using a fluoride ion-specific electrode (Orion #96-909-00), while calcium analysis was performed using atomic absorption spectrometry. The data were analyzed using one-sample t-tests and one-way ANOVA. Results: The study found significantly lower fluoride and calcium levels (P< 0.05) in water filtered through PUR, Brita, and AIBERLE filters than in unfiltered water, whereas water filtered through Waterdrop, WINGSOL, and MIST filters had higher levels of fluoride and calcium. Overall, the differences between filtered and unfiltered water were minor for fluoride (up to 4% reduction) but more substantial for calcium (up to 25% reduction). (Am J Dent 2026;39:187-192).

 

Clinical significance: The evaluated faucet-mounted water filters do not affect fluoride concentrations in tap water and thus the effectiveness of community water fluoridation in a clinically significant manner; however, some filters may reduce calcium concentrations significantly.

 

 

Mail: Dr. Frank Lippert, Department of Biomedical and Applied Sciences, Oral Health Research Institute, Indiana University School of Dentistry, 415 Lansing St., Indianapolis, IN 46202 USA.  E-mail: flippert@iu.edu

 

 

 

_______________________________________________________________________________________________________________________________________________________________

                                                                                                                                                  Research Article

_______________________________________________________________________________________________________________________________________________________________

Effect of office bleaching on the color change and roughness of leucite reinforced CAD-CAM materials in different surface finishing protocols stained with common beverages: A laboratory study

 

Zahide Aydin, dds, Çağla Yeşil, dds  &  Zeynep Yeşil, dds, phd

 

Abstract: Purpose: To evaluate in the laboratory the effect of an in-office whitening agent on color change, translucency, and surface roughness of leucite-reinforced CAD-CAM material with different surface finishes exposed to different beverages [cola, tea, fruit juice, coffee, distilled water (Control)]. Methods: All the IPS Empress CAD-CAM ceramic block specimens were treated with a glaze layer (n=75) and then randomly divided into three groups. The samples (n=25) in Group 1 (Control) were not treated (glaze layer remained). The glaze layer of the other samples (n=50) was abraded by the same researcher. While the samples in Group 2 were treated with Optrafine (Optrafine after glazing) (n=25), those in Group 3 were subjected to surface treatment with Eve polishing kits (Eve kit after glazing) (n=25). The samples were then immersed in five different beverages (cola, coffee, tea, fruit juice and distilled water) (n=5) and clinic-type bleaching was applied. Color measurements were recorded by spectrophotometer and surface roughness (Ra) values were recorded by profilometer. Color change (DE00) values were calculated using the CIE2000 formula. The data were statistically analyzed using Shapiro-Wilk test, ANOVA and Bonferroni test (P< 0.05). Results: Regardless of the surface finishing process and beverage, the mean values of color change (DE00) did not differ according to time (P= 0.148). As a result of the ANOVA, surface finishing process, beverage, and time interaction were found to be very significant (P< 0.001). Regardless of the surface finishing process and beverage, it was determined that the mean roughness values differed according to time (P= 0.019). (Am J Dent 2026;39:193-200).

 

Clinical significance: Although bleaching glass ceramic restorations with bleaching agents containing 40% hydrogen peroxide was effective to remove stains, maintaining the glaze surface finish is critical for color stability and surface integrity of CAD-CAM ceramics.

 

Mail: Prof. Dr. Zeynep Yeşil, Ataturk University, Faculty of Dentistry, Department of Prosthodontics, Erzurum, Turkey. E-mail: zyesilz@hotmail.com

 

 

 

_______________________________________________________________________________________________________________________________________________________________

                                                                                                                                                  Research Article

_______________________________________________________________________________________________________________________________________________________________

Influence of the amount of dentifrice used for brushing on enamel and dentin abrasion

 

Shaira Rahielah Kasi, dds,  Rafaela Oliveira Pilecco, dds, phd,   Lucas Saldanha da Rosa, dds, phd, João Paulo Mendes Tribst, dds, phd,  Cornelis Johannes Kleverlaan, phd,  Mutlu Özcan, dds, phd & Albert Joseph Feilzer, dds, phd

 

Abstract: Purpose: To investigate whether the amount of dentifrice (dose) used per brushing affects the abrasion of the hard tooth tissues. Methods: Enamel and dentin specimens were subjected to simulated brushing with two commercial dentifrices (Prodent, Smyle dentifrice in tablet form) and positive as well as negative controls at varying amounts of dentifrices (standard dose, half, and double dose). Brushing without dentifrice (with water) functioned as a negative control. Tooth wear was quantified using profilometry, and statistical analysis was performed using one-way ANOVA and Tukey’s post hoc test (α= 0.05). Results: For enamel, dose variations had minimal impact. However, dentin wear increased significantly with higher doses, particularly for the positive control and Smyle at double dose (P< 0.05). Dilution reduced abrasivity inconsistently across brands. (Am J Dent 2026;39:201-205).

 

Clinical significance: The amount of dentifrice used for brushing has a significant, dose-dependent effect on dentin abrasion, whereas enamel is relatively unaffected, and brushing without dentifrice does not cause wear. While dentifrice in tablet form provides a manufacturer‑defined standard amount per brushing, this is not the case for dentifrice in paste form. Because the amount of dentifrice used influences dentin wear, it is advisable that manufacturers clearly define the recommended quantity of dentifrice for a single brushing.

 

Mail: Prof. Albert Feilzer, Department of Dental Materials and Reconstructive Oral Care, Academic Center for Dentistry (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Gustav Mahlerlaan 3004, 1081LA Amsterdam, The Netherlands.  E-mail: a.feilzer@acta.nl

 

 

 

 

_______________________________________________________________________________________________________________________________________________________________

                                                                                                                                                  Research Article

_______________________________________________________________________________________________________________________________________________________________

Perioperative nursing based on the Knowledge-Attitude-Practice theory in patients undergoing robot-assisted dental implant surgery

 

Meiling Shen, mm, Yi Feng, bs, Xinwen Peng, bs,  Yan Chen, bs, Tong Cheng, bs, Kangwen Yang, bs &  Jianfang Huang, bs

 

Abstract: Purpose: To investigate the clinical effectiveness of perioperative nursing interventions based on the Knowledge–Attitude–Practice (KAP) theory in patients undergoing robot-assisted dental implant surgery. Methods: A total of 54 patients who underwent robot-assisted dental implant surgery were allocated to either a conventional perioperative care group (control group) or a KAP intervention group. The control group received routine perioperative care according to the hospital’s standard protocols, whereas the intervention group received perioperative care based on the KAP theory in addition to the standard care. The KAP-based care followed a progressive pathway characterized by knowledge dissemination, attitude cultivation, and behavioral guidance. The intervention period lasted for 8 weeks. Primary outcome measures included self-care ability, negative emotions, postoperative swelling and pain, follow-up compliance, and patient satisfaction. Results: After 8 weeks, the intervention group exhibited significantly greater improvements in all domains of self-care behavior (regular follow-up, correct toothbrushing, and balanced diet) as well as in total self-efficacy scores compared with the control group. Dental anxiety and dental fear scores decreased significantly in both groups, with greater reductions in the intervention group. Postoperative pain scores were significantly lower and satisfaction scores significantly higher in the intervention group. At 3 and 6 months, compliance rates in the intervention group were significantly higher than those in control group. (Am J Dent 2026;39:206-210).

 

 

 

Clinical significance: Perioperative nursing based on the Knowledge–Attitude–Practice (KAP) theory enhanced self-care ability, alleviated negative emotions, increased long-term follow-up compliance, and improved patient satisfaction in individuals undergoing robot-assisted dental implant surgery. This model effectively standardizes patient care behaviors and optimizes postoperative recovery.

 

Mail: Ms. Jianfang Huang, School & Hospital of Stomatology, Wuhan University, No. 237 Luoyu Road, Hongshan District, Wuhan City, Hubei Province, 430000 China. E-mail: huangjianfang@whu.edu.cn

 

 

_______________________________________________________________________________________________________________________________________________________________

                                                                                                                                                  Research Article

_______________________________________________________________________________________________________________________________________________________________

The impact of different cavity design parameters on intraoral scanner accuracy in endocrown restorations

 

Yunus Emre Ozden, dds, phd,  Idil Ozden, dds,  Zeynep Ozkurt Kayahan, dds, phd &  Ender Kazazoglu, dds, phd

 

Abstract: Purpose: To evaluate the effects of different tooth structure thicknesses and cavity depths on the accuracy of intraoral scanners (IOS) in endocrown restorations. Methods: A mandibular typodont model was used, with the left mandibular first molar replaced by an extracted real human tooth. Endocrown cavities with varying depths (3.5 mm and 5 mm) and remaining wall thicknesses (1.5 mm and 0.5 mm) were prepared. Master models were scanned using a high-precision extraoral scanner, and the data were exported in STL format. Ten intraoral scans were performed for each group using the Trios 3 IOS. Scanning accuracy was analyzed using the Root Mean Square (RMS) value for trueness and the Interquartile Range (IQR) for precision in Geomagic Design X software. The differences in RMS values among the groups were examined using Independent Samples T test and one-way ANOVA test. Results: Significant differences in RMS and IQR values were observed between groups with different cavity depths and remaining tooth structure thicknesses (P< 0.001). Groups with thinner remaining tooth structures and deeper cavities exhibited greater deviations, indicating reduced scanning accuracy. (Am J Dent 2026;39:191-196).

 

 

Clinical significance: Cavity depth and tooth structure thickness significantly influenced the accuracy of intraoral scanners in endocrown restorations.

 

Mail: Dr. Idil Ozden, Basibuyuk Road Marmara University, Health Campus 9/3, 34854 Maltepe, Istanbul, Turkey. E-mail: idil.akman94@gmail.com

 

 

Logo


© Copyright 1987-2026
American Journal of Dentistry
All Rights Reserved

only search The American Journal of Dentistry